NEW QUESTION # 77
What is the difference between a single bus and a dual bus power distribution system?

  • A. Single bus is more flexible and adaptable to changing needs than dual bus
  • B. Single bus has only one power source while dual bus has two independent power sources
  • C. Dual bus is more cost-effective than single bus
  • D. Single bus is more reliable than dual bus

Answer: B


NEW QUESTION # 78
What are the different generator ratings?

  • A. Normal, Redundant and Fault-tolerant
  • B. Standard, Backup and Emergency
  • C. Primary, Secondary and Tertiary
  • D. Prime, Continuous and Standby

Answer: D


NEW QUESTION # 79
What is the second preference regarding utility service?

  • A. At least One Circuit from two Separate Substations and Different Voltage Levels
  • B. Two balanced feeds with different voltages derived from a single distribution station
  • C. One balanced feeder coordinated with upstream backup feed
  • D. At least four circuits each from different distribution stations but fed via common feeders

Answer: A


NEW QUESTION # 80
What is the recommended floor loading capacity for a data center?

  • A. 2000 lbs per sq. ft.
  • B. 1250 lbs per sq. ft.
  • C. 1500 lbs per sq. ft.
  • D. 1000 lbs per sq. ft.
  • E. 1750 lbs per sq. ft.

Answer: C


NEW QUESTION # 81
What's conservative' hydrogen maximum flow rate per minute for battery.

  • A. 61 cm/m²
  • B. 500 cm/m²
  • C. 21 cm/m²
  • D. None of these answer

Answer: C


NEW QUESTION # 82
where should engineering offices be located?

  • A. adjacent to equipment rooms they support
  • B. inside computer room
  • C. in a separate building
  • D. far away from the data center

Answer: A


NEW QUESTION # 83
What is the appropriate fire rating requirements for an electrical room?

  • A. 1 hour
  • B. 3 hours
  • C. 1/2 hour
  • D. 2 hours

Answer: A


NEW QUESTION # 84
what is the hydrogen maximum for a data center?

  • A. 1 % of total room volume
  • B. None Of These answers
  • C. 20%of total room volume
  • D. 15%of total room volume

Answer: A


NEW QUESTION # 85
what is the ASHRAE maximum relative humidity recommended.

  • A. 45%
  • B. 55%
  • C. 60%
  • D. 50%

Answer: C


NEW QUESTION # 86
What are the speed and distance limitations of ESCON?

  • A. 10 Gbps @ up to 40km
  • B. 17 MB/s @ up to 60km
  • C. 100 Mbps @ up to 20km
  • D. 1 Gbps @ up to 100m

Answer: B


NEW QUESTION # 87
What level should the battery room be on?

  • A. Lower Floor
  • B. None
  • C. Upper floor
  • D. All
  • E. Grade Level

Answer: E


NEW QUESTION # 88
what is the minimum thickness of an elevated floor topping over metal flutes?

  • A. 2 inchmhes
    B, 3 Inches
  • B. 1,5Inchessa.i:sab#v=onepage&q&f=.htm&ebrary=&qp=end+user+bicsi+f2590b67561c7dcea431ec3e26ae
  • C. 4 Inches

Answer: B


NEW QUESTION # 89
What's the maximum number of racks in an aisle if one end has no exit?

  • A. 10 racks
  • B. 15 Racks
  • C. 5 racks
  • D. It doesn't matter

Answer: A


NEW QUESTION # 90
What is the recommended range for the high temperature in a data center according to NEB?

  • A. 85 degrees
  • B. 80 degrees
  • C. 90 degrees
  • D. 75 degrees
  • E. 70 degrees

Answer: B


NEW QUESTION # 91
What is the difference between a hard-wired and a plug-in UPS?

  • A. Hard-wired UPS is permanently connected to the electrical system while plug-in UPS can be easily connected and disconnected
  • B. Plug-in UPS is more cost-effective than hard-wired UPS
  • C. Hard-wired UPS is more reliable than plug-in UPS
  • D. Hard-wired UPS is more efficient in terms of power delivery than plug-in UPS

Answer: A


NEW QUESTION # 92
What is the minimum separation distance of underground telecommunications and utility cabling in same route?

  • A. 2 feet minimum along entire route
  • B. 6 feet minimum along entire route
  • C. no need for separation as long as they are enclosed in different conduit systems.
  • D. none of the above

Answer: B


NEW QUESTION # 93
Where is temperature typically measured in a data center HVAC system?

  • A. At the server rack exhaust
  • B. At the CRAC unit inlet
  • C. At the CRAC unit exhaust
  • D. At the server rack inlet

Answer: B


NEW QUESTION # 94
What is the minimum access floor to ceiling height recommended?

  • A. 11ft minimum
  • B. 8 feet minimum
  • C. 10 feet minimum
  • D. 9 feet minimum

Answer: C


NEW QUESTION # 95
Where should the entrance room be located within a data center?

  • A. Adjacent to or in a secured space within the computer room
  • B. Anywhere with easy access to the outside
  • C. In a separate building on the campus
  • D. In the computer room

Answer: A


NEW QUESTION # 96
what is the ANSI/TIA-942 recommended operational temperature

  • A. 60F to 75F
  • B. -10°C to +45°C
  • C. 80F to 90F
  • D. 68F to 77F

Answer: D


NEW QUESTION # 97
What specific power consumption should be used to measure PU E?

  • A. only that which directly supports the data center like electrical distribution and cooling equipment
  • B. What can directly support operations without including power utilization How much energy a particular device utilizes per unit of time?
  • C. Proportion between IT subsystem's input vs output capacities over some period.
  • D. Maximal consumption across all measured devices in a specified amount of time.

Answer: A


NEW QUESTION # 98
What Enhanced Fujita Scale level is commonly used in wind loading calculations?

  • A. EF1,73-112 mph
  • B. EF3,158-206mph
  • C. EF2,113-157mph
  • D. EF4,207-260 mph

Answer: D


NEW QUESTION # 99
What is the minimum sized conductor from the rebar mat foundation to the mesh bonding network?

  • A. 8 AWG
  • B. 6 AWG
  • C. 2 AWG
  • D. 4 AWG

Answer: D


NEW QUESTION # 100
Which network topology uses the least amount of cabling?

  • A. Top of Rack
  • B. Star
  • C. Bus
  • D. Mesh

Answer: A


NEW QUESTION # 101
where should the telecommunications room for the operations center be located

  • A. in an offsite location
  • B. inside the computer room
  • C. on another floor entirely from the operations center
  • D. within a designated telecommunication space outside of computer rooms

Answer: D


NEW QUESTION # 102
......